What was found
CORROSION ON FLOORBEAM BS 1110, RBL 22, WL 208. CUT OUT CORRODED SECTION OF FLOORBEAM'S TOP CHORD BS 1110 WL 208 RBL 8-23 AND INSTALLED REPAIR ANGLES, TEE CHORD AND STRAPS PER SRM 53-10-8.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON FLOORBEAM BS 1110, RBL 22, WL 208. CUT OUT CORRODED SECTION OF FLOORBEAM'S TOP CHORD BS 1110 WL 208 RBL 8-23 AND INSTALLED REPAIR ANGLES, TEE CHORD AND STRAPS PER SRM 53-10-8.