What was found
DURING C-CHECK INSPECTION, CORROSION WAS FOUND IN THE CENTER BORE OF THE ANB7016-6 RT INBOARD FLAP DRIVE BEARING MOUNT BORE. THE SUBJECT CORROSION WAS REMOVED BY OVERSIZING THE SUBJECT HOLE TO 1.0210 INCH DIA. REMOVED FITTING IAW DC10 SRM 51-31-00 VOL II. REMOVED CORROSION IAW DC10 SRM 57-20-00 VOL 1. FABRICATED AND INSTALLED BUSHING IAW FEDEX EA 8-5710-75080 AND DC10 SRM 57-20-00 VOL 1. CORROSION LEVEL 1. FITTING INSTALLATION COMPLETED ON FEDEX CARD N02040.