What was found
MAIN CARGO COMPARTMENT CORROSION ON FLOORBEAM BS 344 WL 208 BL 0 TO LBL 45. REMOVED CORROSION ON FLOORBEAM STA 344, LBL 38, 2 X 8 X .020 FOUND OUT OF LIMITS IAW SRM 51-10-1. REMOVED AND FABRICATED NEW FLOOR BEAM BS 344, WL 208, RBL 6 TO LBL 65 (SKIN) BAC 1505-29222 7075-T6511 LOT 540294 IAW SRM 51-30-5. FABRICATED 4 EACH SPLICE ANGLES BAC 1410-2773, 7075-T6 LOT 540292 IAW SRM 53-10-8 FIG 9. ALODINED AND PRIMED PER SOPM 20-41-02. INSTALLED UPPER CHORD AND 4EA SPLICE ANGLES IAW SRM 53-10-8 FIG 9.