As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
MAIN DECK CARGO COMP BETWEEN 3 AND 4 SEAT TRACK FROM CENTER LINE, FLOOR PLATE PANEL HAS 3EA AREA OF CORROSION BETWEEN FR25 AND FR26. BLENDED OUT COROSION FOUND TO BE OUT OF LIMITS IWA A300-600 SRM 51-74-10 AND 53-10-00. REMOVED THRUST PLATE AND REINSTALLED OLD ANGLE FROM PLATE AND RE-INSTALLED ON NEW PLATE IAW A300-600 SRM 51-72-10 AND 51-40-21, AND INSTALLED NEW THRUST PLATE IAW A300-600 SRM 51-72-10 ABD 51-40-21.