What was found
CORROSION STA 760 DELTA BEAM LWR ANGLE HAS CORROSION. REMOVED CORROSION, FOUND TO BE OUT OF LIMITS BS 760 DELTA BEAM LWR ANGLE. REMOVED AND INSTALLED NEW BS 760 DELTA BEAM LWR ANGLE IAW SRM 51-30-2, 51-10-6 STEP 7, 51-10-1 FIG 1, 51-30-5.