What was found
AVI BAY FROM FR 7 TO 10 STR 48L TO 48R E&E GROUND ACCESS DOOR CUTOUT SKIN SURFACE, FRAME ATTACHING SUPPORT ANGLES, PLATES, FITTINGS & FASTENERS HAVE CORROSION OVER ENTIRE CUTOUT AREA. REMOVED CORROSION AT AVI BAY FR 7 TO 10 STR 48L TO 48R, DOOR CUTOUT SKIN SURFACE, FRAME, SUPPORT ANGLES, PLATES, FITTINGS. ALL AREAS WITHIN LIMITS, FRAME SECTION NR 7 OUT OF LIMITS. REMOVED CORRODED SECTION OF FRAME NR 7 & ATTACHING PARTS. REINSTALLED NEW SECTION OF FRAME NR 7, RE-INSTALLED ATTACHING PARTS PER A310 SRM 51-40-21, 51-22-00, 51-74-10, 51-72-10.