What was found
ON FLAP RETRACTION AFTER T/O, GOT A FLAP DISAGREE LEVEL 2 ALERT. CONFIG PAGE SHOWED FLAPS STILL AT 18 DEG T/O SETTING. ACCOMPLISHED QRH PROCEDURES WITH RESULTS OF INABILITY TO RAISE OR LOWER FLAPS AT ALL. LANDED AT FLAPS 18 DEG/ EXT. CONFIG PAGE SHOWED FLAPS AT 19/21 & 20/19. FLAP HANDLE DURING TROUBLESHOOTING WAS RAISED TO 0 DEG/EXT AND LOWERED TO 35/EXT WITH NO CHANGE. FOUND DIAL-A-FLAP OUT OF SEQUENCE. RESET FLAP AND SLAT HANDLES REF MM 27-50-00-5. OPS CHECK NUMEROUS TIMES ALL NORMAL OPERATION.