What was found
RIGHT FWD (WING SIDE) O/B FLAP O/B HINGE - SPOTFACE AT BARREL NUT AREA FOUND CORRODED. RIGHT FWD (WING SIDE) O/B FLAP O/B HINGE - SPOTFACE AT BARREL NUT AREA CORROSION REMOVED AS PER CM 57-44-09 PAGES 402-407, AND FOUND WITHIN LIMITS AS PER DWG ARC0503 SHT 2. ORIGINAL THICKNESS =0.430 INCH, MATERIAL REMOVED =0.002 INCH, REMAINING THICKNESS =0.428 INCH.