What was found
STA 600 FRAME DENTED BETWEEN STR 24 LT & 25 LT IN FWD CARGO BAY. FRAME AT BS 600 BETWEEN STR 24 LT & 25 LT IN FWD CARGO BAY DENT FOUND OUT OF LIMITS PER SRM 53-10-1. REPAIR FRAME PER SRM 51-40-3 AND FED EX EA 7-5310-70665.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
STA 600 FRAME DENTED BETWEEN STR 24 LT & 25 LT IN FWD CARGO BAY. FRAME AT BS 600 BETWEEN STR 24 LT & 25 LT IN FWD CARGO BAY DENT FOUND OUT OF LIMITS PER SRM 53-10-1. REPAIR FRAME PER SRM 51-40-3 AND FED EX EA 7-5310-70665.