What was found
RIGHT HAND WING STATION XW255.000, LOWER SPAR BEAM OUTBOARD HOLE "C" ON PAGE 9 OF 18 OF EO 8-5750-7-5001 PART 2, HOLE HAS TOOLING DAMAGE. REAMED HOLE TO FINAL SIZE OF 1.0022, ALODINE BORE IAW EA 8-5710-77571, FABRICATED BUSHING IAW EA 8-5710-77571, PERFORMED FPI INSPECTION OF BUSHING IAW DAC SPM 20-30-02 AND EA 8-5710-77571. NO DEFECTS NOTED. CAD PLATING ACCOMPLISHED BY OUTSIDE VENDOR ON PO NR 448912. INSTALLED RIGHT HAND WING BUSHING STATION XW 255.000 LOWER SPAR BEAM OUTBOARD HOLE, HOLE "C", PER PAGE 9 OF 18 OF EO 8-5750-7-5000 PART 2 IAW EA 8-5710-77571.