What was found
MAIN DECK CABIN AT STA 775 (RT) WIRE NR`S. C029-1-6AL, C029-2-6AL AND C029-3-6AL FND BURNT. GVI ON THE BURNT WIRES SURROUNDING AREAS,CONDUCTIVITY INSP PER DAC NDT SPM PART 06-10-01-001 REV11 ON M/D STA 775R FRAME/SKIN FND ACCEPTABLE RANGE. BURNT CABLES, REPAIRED USING COPALUM SPLICE PER BOEING SWPM20-30-13, CONDUCTIVITY/INSULATION. RESISTANCE CHECK PER SWPM29-21-01 SATIS. AIRPLANE POWER ASSURANCE CHECK/PHASE IMBALANCE TEST CARRIED OUT ON BOTH AUX HYD PUMP SATIS PER AMM29-21-01, SUBSEQUENT OPS CHK CARRIED OUT ON BOTH AUX HYD PUMPS. ALSO, FOUND SATIS PER AMM29-21-01-700-801. FEDEX EA 1-2920-79801 'HYD POWER-AUXILIARY HYD PUMP WIRING, SPLICE REPAIR COMPLIED WITH.