As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
MAIN DECK - SPLICE FITTING AT RT STA 1531 LONGERON 14 CRACKED. MAIN DECK - SPLICE FITTING AT RT STA 1531 LONGERON 14 REMOVED AS PER SRM 51-31-01 VOLUME 2. NEW SPLICE FITTING FABRICATED AS PER DWG A5A7112 AND INSTALLED AS PER SRM 51-31-01 VOLUME 2.