What was found
LEFT WING, OUTBOARD FLAP INBOARD FORWARD HINGE, LOWER MOUNT MATING SURFACE FOUND CORRODED. LEFT WING, OUTBOARD FLAP INBOARD FORWARD HINGE, LOWER MOUNT MATING SURFACE CORROSION REMOVED AS PER CMM 57-44-08 PAGES 402-407. ORIGINAL THICKNESS=0.470 INCH, MATERIAL REMOVED=0.002 INCH, REMAINING THICKNESS=0.468 INCH, AND FOUND WITHIN LIMITS AS PER DRAWING ARC0502.