What was found
AFT CARGO LEFT SIDE FLOORBOARD SUPPORT CROSS MEMBER HAS EXFOLIATION CORROSION AT FRAME 60. CUT DAMAGED SECTION IAW A310-200 SRM 53-10-15, VERIFIED MAT'L TO FAB, FABBED REPAIR ANGLE AND FILLER, LOCATED, DRILLED DEBURRED AND COUNTERSUNK IAW A310 SRM 51-40-44. TREATED, PRIMED AND TOP COATED IAW A310 SRM 51-23-22. INSTALLED REPAIR ANGLE IAW SRM 53-10-15.