What was found
CORROSION FOUND BETWEEN STA 6-50 AND STA 6-70 AT LONGERON 15L. REMOVED AS PER MD-11 SRM 51-31-01 VOLUME I. NEW LONGERON FABRICATED AS PER DWG NO.: ADA3011 AND FABRICATED LONGERON INSTALLED AS PER MD-11 SRM 51-31-01 VOLUME I.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION FOUND BETWEEN STA 6-50 AND STA 6-70 AT LONGERON 15L. REMOVED AS PER MD-11 SRM 51-31-01 VOLUME I. NEW LONGERON FABRICATED AS PER DWG NO.: ADA3011 AND FABRICATED LONGERON INSTALLED AS PER MD-11 SRM 51-31-01 VOLUME I.