What was found
FWD CARGO COMPARTMENT FRAME DENTED STA 500 BETWEEN STR 22L AND 23L. *S/D* REMOVED DAMAGE AREA OF FRAME BS 500 FABRICATED, ALODINED, PRIMED AND INSTALLED REPAIR IAW SRM 51-40-3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD CARGO COMPARTMENT FRAME DENTED STA 500 BETWEEN STR 22L AND 23L. *S/D* REMOVED DAMAGE AREA OF FRAME BS 500 FABRICATED, ALODINED, PRIMED AND INSTALLED REPAIR IAW SRM 51-40-3.