What was found
MAIN DECK, RT SIDEWALL STRUCTURE FRAME'S INNER CHORD DENT AT STA 1721, L-12R. FRAME AT STA 1721 RT SIDEWALL L-12R DENTED AREA REPAIRED AS PER SRM 53-30-00 VOL I FIG 1. REPAIR IS CAT B INITIAL INSPECTION AT 14,500 AND REPETITIVE INSPECTION REQUIRED AT 9,500 LANDINGS. REFER TO EA NR 1-5310-76835, TITLE:FUSELAGE MAIN FRAME, TRACKING SRM REPAIR ON FRAME AT STATION 1721, LONGERON 12R.