As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
BULK CARGO COMPT. FLOOR STRUCTURE, ON RT SIDE FR 66 TO FR 63 CORROSION ON TOP AND BENEATH SURFACE. REMOVED CORROSION IAW SRM 51-70-10 AND FOUND TO BE OUT OF LIMITS IAW SRM 53-10-16. REMOVED AND REPLACED BEAM IAW SRM 51-40-21.**** S/D COMING ****