Service difficulty report · Bleed Valve · Airbus A300B4622

Difficulty date
September 17, 2004
Submitted
September 21, 2004
Operation
Air carrier
Aircraft
N716FD
Make and model
Airbus A300B4622
Aircraft serial
358
Aircraft time
27,670 hours, 30,202 cycles
Engine
Iae V2524A5
Part
Bleed Valve
Part number
6272484
Part serial
062C10356
Condition
Malfunctioned
Location
Nr 1 Engine
Part time
2,135 hours, 1,323 cycles
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

BLEED VALVE 1 FAULTED AFTER TAKEOFF. NO RESET, RAN NR 1 ENG AT THE GATE. NO FAULTS NOTED. RAN ENGS AT T/O POWER FOR 5 MIN. NO FAULTS NOTED. INTERROGATED PNEU SYST CONTROLLERS. NO FAULTS STORE IN MEMORY FOR ANY FLIGHT LEG, STILL T/S. TALKED TO MOCC. SINCE THERE WAS NO FAULTS STORED, AGREED TO REMOVE AND REPLACE THE CONTROLLERS AS PRECAUTIONARY. RAN ENG AT THE GATE, PERFORMED VALVE SWITCH OVER FROM HIGH STAGE TO LOW STAGE. OPS CK GOOD. NO FAULT NOTED IAW A300 JRH.