What was found
MAIN DECK - ATTIC AREA STA 1538 LONGERON 6R LONGERON SPLICE FOUND CRACK. NEW LONGERON SPLICE FABRICATED AS PER DWG NR A5A7112. CRACKED LONGERON SPLICE REMOVED & REPLACED AS PER SRM51-33-01 VOL 2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN DECK - ATTIC AREA STA 1538 LONGERON 6R LONGERON SPLICE FOUND CRACK. NEW LONGERON SPLICE FABRICATED AS PER DWG NR A5A7112. CRACKED LONGERON SPLICE REMOVED & REPLACED AS PER SRM51-33-01 VOL 2.