What was found
WHILE DESCENDING ON GLIDESLOPE, ELEVATOR LOW PRESSURE LIGHT FLICKERED, CROSS CHECKED WITH HYDRAULIC PANEL AND NOTICED "A" SYSTEM AT ABOUT 1 QT. C/W QRH PROCEDURES. ENT BY: 448879 ADDED MPN BACH8A06NN0300T CPN 0109172 QTY 1 HOSE MSN 904416 ENT BY: 448879 . FOUND BRAIDED LINE ON LT BODY GEAR DOOR ACTUATOR RUPTURED. ORDERED HOSE CPN 0109172 MSN 904416. ENT BY: 448879 FACT 02NOV04 22:35 MCI R. REMOVED AND REPLACED BODY DOOR ACTUATOR LINE FOLLOWING FX MM 32-32-081-4, LEAK CHECK GOOD. ALSO, FOLLOWED FX MM 29-11-000-1 CASE DRAIN AND PRESSURE FILTER CHECK/REPLACEMENT. NO CONTAMINATION FOUND. LEAK CHECK GOOD. ENT BY: 393294 RPT BY: 393294.