What was found
LT WING UPPER SURFACE STA XOS=772, ON PREVIOUS METAL FILLER REPAIR FOUND EXISTING BLENDOUT EXCEEDED SRM 57-10-00, VOLUME 1, FIGURE 32 SHEET. NR 2 LIMITS. BLENDOUT DIMENSION: LENGTH=1.5 INCH, WIDTH= 1.25 INCH, DEPTH=0.0052 INCH; ORIGINAL THICKNESS= 0.312 INCH, REMAINING=0.262 INCH. L/H WING, TAPERED UPPER CENTER, OUTER SKIN PANEL SURFACE LOCATED AT STA XROS= 772, FRONT SPAR LINE - EXISTING BLENDOUT REPAIR CARRIED OUT PER SRM 57-10-00, VOLUME 1, FIGURE 32 SHEET 2 AND 9. COMPLIED WITH FEDEX EA 1-5720-77972, WINGS - LT HAND TAPERED UPPER / CENTER OUTER SKIN PANEL - REWORK