As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
BULK CARGO COMPT FLOOR STRUCTURE FR 67 LT TO MID RT SIDE HAS MULTIPLE AREAS OF CORROSION FROM TOP SKIN TO UNDERNEATH SURFACE. REMOVED CORROSION, FOUND TO BE OUT OF LIMITS IAW SRM 53-10-00. REMOVED AND REPLACED BEAM IAW SRM 51-40-21 AT FR 67.