What was found
VERTICAL STAB R&L TIP ATTACH FLANGES CORRODED AROUND HOLES AND UNDER NUT PLATES. REMOVED AND REPLACED RIB FLANGES IAW A310-200 SRM 51-72-10. APPLIED SURFACE PROTECTION IAW A310-200 SRM 51-73-10.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
VERTICAL STAB R&L TIP ATTACH FLANGES CORRODED AROUND HOLES AND UNDER NUT PLATES. REMOVED AND REPLACED RIB FLANGES IAW A310-200 SRM 51-72-10. APPLIED SURFACE PROTECTION IAW A310-200 SRM 51-73-10.