What was found
WHILE WORKING ROUTINE CARD 7-5330-2342 P1 FOUND GOUGE IN FUSELAGE SKIN CROWN AREA BS 1061 BETWEEN STR 1R & 2R, 35 INCHES FWD OF S-DUCT HOUSING L/E. *S/D* GOUGE FOUND TO BE OUT OF LIMITS, REPAIRED AREA PER SRM 53-30-3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
WHILE WORKING ROUTINE CARD 7-5330-2342 P1 FOUND GOUGE IN FUSELAGE SKIN CROWN AREA BS 1061 BETWEEN STR 1R & 2R, 35 INCHES FWD OF S-DUCT HOUSING L/E. *S/D* GOUGE FOUND TO BE OUT OF LIMITS, REPAIRED AREA PER SRM 53-30-3.