What was found
BULK PIT UNDER FLOOR FR 63 STR 44L HAS AN AREA OF CORROSION EXTENDING UNDER FRAME AND SHEAR TIE. REMOVED DAMAGED SECTION OF STRINGER AND REPAIRED IAW A310-200 SRM 53-10-14.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BULK PIT UNDER FLOOR FR 63 STR 44L HAS AN AREA OF CORROSION EXTENDING UNDER FRAME AND SHEAR TIE. REMOVED DAMAGED SECTION OF STRINGER AND REPAIRED IAW A310-200 SRM 53-10-14.