What was found
BULK PIT UNDER FLOOR STG 50R FROM 10 INCHES AFT OF FR 64 TO FR 65, 1 INCH INBOARD OF STG TO 2 INCHES OUTBOARD OF STG HAS CORROSION EXTENDING ON AND UNDER BRACKETS AND STG SPLICE. REMOVED CORROSION IAW A310-200 SRM 51-74-10. AREA OUT OF LIMITS IAW A310-200 SRM 53-10-00. REMOVED DAMAGED SECTION IAW A310-200 SRM 53-10-14. TREATED AND PRIMED NEW PARTS IAW A310-200 SRM 53-10-44. INSTALLED NEW PARTS IAW A310-200 SRM 51-40-21. APPLIED TOPCOAT IAW A310-200 SRM 51-21-10. APPLIED FILLET SEAL IAW A310-200 SRM 51-76-00.