As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
BULKPIT UNDER FLOOR FR64 FWD 8 INCHES TO AFT 14 INCHES EXTENDING 1 INCH INBOARD AND OUTBOARD OF STG 47R AND EXTENDING UNDER SHEAR TIE AND FRAME. REMOVED CORROSION IAW A310-200 SRM 51-74-10. AREA WAS OUT OF LIMITS IAW A310-200 SRM 53-10-00. REMOVED AND REPLACED DAMAGED AREA IAW A310-200 SRM 53-10-14. TREATED, PRIMED AND TOPCOATED IAW A310-200 SRM 51-21-10. SEALED AREA IAW A310-200 SRM 51-76-00.