What was found
BULK PIT UNDER FLOOR FR 68 FWD 10 IN STR 53R HAS CORROSION AN AREA EXTENDING UNDER SHEAR TIE AND FASTENERS. REPAIRED AREA IAW SRM 53-10-00 FIG 104 AND SRM 53-10-14 REF N00749.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BULK PIT UNDER FLOOR FR 68 FWD 10 IN STR 53R HAS CORROSION AN AREA EXTENDING UNDER SHEAR TIE AND FASTENERS. REPAIRED AREA IAW SRM 53-10-00 FIG 104 AND SRM 53-10-14 REF N00749.