As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
BULK PIT FLOOR SUPPORT AT FR67 FROM 12 INCHES TO LT CTR TO 36 INCHES TO LT OF CTR, 4EA AREAS OF CORROSION EXTENDING UNDER FASTENER HEADS AS MARKED. REMOVED AND REPLACED CROSS BEAM FLOOR SUPPORT IAW 51-72-10. REMOVED 4EA AREAS OF CORROSION IAW SRM 51-74-10.