As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING INSPECTION FOUND AT STA 1701 FROM STR 45 RT TO 45 LT RETAINER WITH CORROSION. REMOVED CORROSION ON RETAINER PER SRM 51-21-01. PERFORMED CHECK LIMITS; THE MATERIAL REMOVED IS WITHIN LIMITS PER SRM 53-00-01. PROTECTED AREA PER SRM 51-21-01. (OPEN)