What was found
PANEL LAND AT 650MB HAS 8 EA ELONGATED HOLES. REPAIRED 5 HOLES IAW A310-200 SRM 51-40-44 FIG 1, AND COMPLIED WITH EA 6-5710-87184 BY INSTALLING 3 EA REPAIR BUSHINGS FOR REMAINING 3 HOLES.