What was found
CABIN, STA 1641-1661 RT LONGITUDINAL SPLICE AT L11 SUSPECT CRACKED AT FASTENERS HOLES AS MARKED. LONGITUDINAL SPLICE AT STA 1641 TO 1661 RT L-11 REMOVED NEW SPLICE, FABRICATED FROM 1D0755T7150T61511 AS PER DRAWING AFA7181. FPI INSPECTION CARRIED OUT AND FOUND NO EVIDENT OF CRACK. FABRICATED SPLICE REPROTECTED AND PART MARK: AFA 7181-509. FABRICATED SPLICE LOCATED AND INSTALLED BETWEEN STA 1641 TO 1661 RT L-11 AS PER DRAWING NFA6009.