What was found
IN AC BAY, FROM FRAME 41 TO 42 AND STGR 51R TO 47R, AREA HAS CORROSION ON SKIN. REMOVED FASTENERS IAW A310-200 SRM 51-40-21. REMOVED CORROSION IAW A310-200 SRM 51-74-10. MATERIAL REMOVED WITHIN LIMITS IAW A310-200 SRM 53-10-00. FLAP PEENED AS REQUIRED IAW A310-200 51-29-00, TREATED, PRIMED, AND APPLIED TOP COAT IAW A310-200 SRM 51-75-10. REINSTALLED FASTENERS IAW A310-200 SRM 51-40-21.