What was found
CABIN, FLOOR SUPPORT FOUND CORROSION AT STA 1911 RBL 70 AND 75 AS MARKED. REMOVED AS PER SRM 51-31-01 VOL II. NEW FLOOR SUPPORT FABRICATED FROM S2929348 AS PER DRAWING AGA 7501 AND REPROTECTED AS PER SRM 51-21-01 VOL II. NEW FLOOR SUPPORT LOCATED AND INSTALLED AT STA 1911 RBL 58-84 AS PER SRM 51-31-01 VOL II.CLASSIFIED MAJOR REPAIR AS PER GMM 6-2-100.