CABIN FLOORBEAM FOUND CORRODED AT STA 1873 LBL 10 TO 26 AS MARKED. REMOVED AND FOUND EXCEED LIMIT AS PER SRM 53-00-01 FIG. 4 VOL I. DISCREPANT FLOOR SUPPORT AT STA 1873 LBL 33 TO RBL 33 REMOVED AS PER SRM 51-31-01 VOL II. NEW FLOOR SUPPORT REWORKED FROM S2929348-12000 AS PER DWG AGA 7975 AND AND HOLES PICK UP AS PER SRM 51-31-01 VOL II. NEW FLOOR SUPPORT REPROTECTED AS PER SRM 51-21-01 VOL II AND PART MARKED FX AGA 7975-15 AS PER GMM 7-0-1001. NEW FLOOR SUPPORT LOCATED AND INSTALLED AT STA 1873 LBL 33TO RBL 33 AS PER SRM 51-31-01 VOL II. CLASSIFIED MAJOR REPAIR AS PER GMM 6-2-100.