As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
A/C FUSELAGE RT SIDE FR 55 STR 39 HAS GOUGES REF N00057. BLENDED AREAS AND CHECKED LIMITS IAW SRM 53-10-00 AND 53-16-12 WITHIN LIMITS IAW SRM 53-10-12 FIG 102. FOLLOW UP INSP REQ AT OR BEFORE 1500FC AS STATED ON EA 6-5330-89211 AND SRM 53-10-12 FIG 102.