STA 1909 TO STA 2007 LBL 60 ALONG FLOOR SUPPORT STRUCTURE FOUND CORRODED. FLOOR SUPPORT REWORKED IAW DWG AGA7496 AND INSTALLED IAW SRM 51-31-01.