As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CABIN AT STA 1887 RBL 35 FLOORBEAM STRUCTURE FOUND CORRODED. CORROSION REMOVED AND REPROTECTED AS PER SRM 51-21-01 VOL II. MATERIAL THK: 0.080" ,THK REMAINED: 0.072" AND MATERIAL REMOVED: 0.008" FOUND WITHIN LIMIT AS PER SRM 53-00-01 FIG 4 VOL I. REWORKED AREA PAINTED AS PER SRM 51-21-01 VOL II. CLASSIFIED MINOR REPAIR AS PER GMM 6-2-100.