What was found
AT STA 1964 LBL 10 FLOOR SUPPORT STRUCTURE FOUND CORRODED. FLOOR SUPPORT REMOVED. NEW FLOOR SUPPORT REWORKED FROM S2929169X7075T6511 AS PER DRAWING AGA 7091 AND INSTALLED AS PER SRM 51-31-01 VOL II. CLASSIFIED MINOR REPAIR AS PER GMM 6-2-100.