As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CABIN, ALONG STA 1887 TO STA 2007 RBL 24 FLOOR SUPPORT STRUCTURE FOUND CORRODED. REMOVED AND REWORKED NEW FLOOR SUPPORT FROM S3932107-12400 AS PER DWG AGA 7497. NEW FLOOR SUPPORT PAINTED, PART MARKED AND INSTALLED AS PER SRM 51-31-01 VOL II. CLASSIFIED MINOR REPAIR AS PER GMM 6-2-100.