What was found
EVALUATE TO DETERMINE IF REPAIR IS MAJOR OR MINOR AND IF REPAIR IS IN ACCORDANCE WITH FAA APPROVED DATA, (EXTERNAL REPAIR BS 1015, STR 29L, BL 0, 9 X 8 INCHES). REMOVED EXISTING REPAIR, INSTALLED FABRICATED REPAIR PER SRM 53-30-3 FIG 3A.