As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
REPAIR ON FLOORBEAM AT STA 1130 BL 0 THRU RBL 18, PREVIOUS REPAIR AT STA 1130 , BL 0 TO RBL 18 NEEDS ENG EVALUATION TO DETERMINE IF MAJOR OR MINOR AND IF REPAIR IS IAW FAA APPROVED DATA. NO ENGINEERING NEEDED. THE REPAIR IS WAS INSTALLED IAW SRM 53-10-8 AND IS A MAJOR REPAIR IAW GMM 6-2-100.