What was found
PASSING FL 330 GOT NR 2 BLEED LEAK LT IAW ECAMS SHUTOFF NR 2 BLEED VALVE. A/C WOULD NOT HOLD CABIN PRESS AT 310,280,OR EVEN 12,000 FT WITH NR 1 PACK. PACK BAY FOUND SENSOR LOOPS TOUCHING THE BLEED AIR SUPPLY DUCT GOING TO THE NR 2 ENG, ALSO FOUND SMALL LEAK AT THE SAME AREA, TIGHTENED BOLTS ON THE FLANGE AND REPOSITIONED LOOPS AND LEAK CHECKED FOUND OK RAN BOTH ENG'S PER 310 JRH. FOUND NO LEAK FAULTS. PERFORMED CABIN PRESS AND CONTROL CK PER MM 21-31-00-5-01. FOUND OK, FOUND WITH BOTH ENG RUNNING THAT THE PRESS WAS NORMAL 32-34 PSI ON EACH ENG, WITH SINGLE PACK OR BOTH PACKS. A/C OK FOR SERVICE.