Service difficulty report · Sensor · Doug MD11

Difficulty date
August 23, 2005
Submitted
August 29, 2005
Operation
Air carrier
Aircraft
N578FE
Make and model
Doug MD11
Aircraft serial
48458
Aircraft time
37,780 hours, 10,417 cycles
Part
Sensor
Part number
20035012007
Part serial
C0076
Condition
Defective
Location
Zone 400
Part time
45,095 hours, 10,216 cycles
Stage of operation
CR
How discovered
O
Nature of condition
N
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

APPROX 2:40 HOURS INTO FLIGHT, LEVEL THREE AIR MANIFOLD 2 FAIL ALERT ILLUMINATED. CLEARED MASTER WARNING AND RAN APPROPIATE QRH LIST. SYSTEM 2 ON THE AIR SYNOPTIC DISPLAYED AS A RED LINE. MANIFOLD 2 MAINTAINED AIR PRESSURE THROUGHOUT REMAINDER OF FLT AND "BLEED AIR 2 OFF" NEVER ILLUMINATED ON THE AIR SYNOPTIC PAGE. A/C DIVERTED INTO CTS. REPLACED DEFECTIVE SENSORS D1-29 AND D1-28. REPLACED MFC PRECAUTIONARY.