What was found
ENGINE 2 REV UNLK LT COMES ON ABOVE APPROX 35 N1. ABORTED TO AND RETURNED TO RAMP. REMOVED ELECTRICAL CONNECTORS ON RT AND LT CENTER ACTR SEC LOCK SW AND LT AND RT CENTER ACTUATOR STOW AND DEPLOY SWITCHES. CLEANED AND REINSTALLED ELECTRICAL CONNECTORS. RAN ENGINE TO 47 N1, SYSTEM OPS CHECKS NORMAL PER MM 78-30-00-2.