What was found
CORROSION ON FLOORBEAM AT STA. 344 FROM BL 12 L TO BL 12 R. REMOVED CORROSION FROM FLOOORBEAM UPPER CAP IAW FED-EX SRM 53-10- 1. REMOVED, FABRICATED AND INSTALLED SPLICES AND FLOORBEAM IAW SRDM SR27-53-007, B727 SRM 51-10-2,51-30-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON FLOORBEAM AT STA. 344 FROM BL 12 L TO BL 12 R. REMOVED CORROSION FROM FLOOORBEAM UPPER CAP IAW FED-EX SRM 53-10- 1. REMOVED, FABRICATED AND INSTALLED SPLICES AND FLOORBEAM IAW SRDM SR27-53-007, B727 SRM 51-10-2,51-30-2.