What was found
NR 2 ENGINE GENERATOR WILL NOT COME ON LINE, HAS 0 VOLTS AND 0 FREQUENCES. REMOVED AND REPLACED NR 2 ENGINE CSD IAW DC10 M/M 24-11-09-2. SERVICED NR 2 CSD IAW DC10 M/M 24-10-00. OPS CHECK GOOD IAW DC10 M/M 24-11-09 .
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
NR 2 ENGINE GENERATOR WILL NOT COME ON LINE, HAS 0 VOLTS AND 0 FREQUENCES. REMOVED AND REPLACED NR 2 ENGINE CSD IAW DC10 M/M 24-11-09-2. SERVICED NR 2 CSD IAW DC10 M/M 24-10-00. OPS CHECK GOOD IAW DC10 M/M 24-11-09 .