What was found
FOUND CRACK IN STUB FRAME UPPER FLANGE IN FWD CARGO BAY BILGE AT BS 613, STR 26R. REPLACED STUB FRAME AT BS 613 STR 26R PER SRM 51-30-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND CRACK IN STUB FRAME UPPER FLANGE IN FWD CARGO BAY BILGE AT BS 613, STR 26R. REPLACED STUB FRAME AT BS 613 STR 26R PER SRM 51-30-2.