What was found
FOUND LOWER FUSELAGE, CENTER CARGO DOOR CUTOUT FORWARD LOWER AREA FOUND WITH DENTS. TRIMMED OUT AS PER SRM 53-50-00 FIGURE 16 VOLUME I. HFEC INSPECTION CARRIED OUT AS PER NDTSPM PART 06-10-01-001 REV 12 ON THE PERIPHERY OF TRIMMED EDGE AND FOUND NO CRACK EVIDENT. FILLER AND REPAIR DOUBLER FABRICATED AS PER SRM 53-50-00 FIGURE 16 VOLUME I AND INSTALLED AS PER SRM 51-33-01 VOLUME II. REPAIR CLASSIFIED AS MINOR AS PER GMM 6-2-100.